Indian Railway main logo Welcome to Indian Railways View Content in Hindi
View Content in Hindi
National Emblem of India

About CLW

Department

Loco Portal

News & Recruitment

Vendor Information

Tender Information

Contact Us



SMS Inquiry


Bookmark Mail this page Print this page
QUICK LINKS
Download LOCO Software for GTO MICAS VCU

Trial Test SOFTWARE for Energy Saving in Three Phase Freigh Loco (02.03.2021)

Energy Saving in WAG-9/9H
Downloading Software  for energy saving in GTO based WAG-9/9H.
S/W version will appear as
         1. 3203 for SLG-1/2 for WAG-9, 
        2. 4203 for SLG-1/2 for WAG-9H
        3. New BUR-2 software.
 
Conditions for activating energy saving mode are:
        a. TE/BE should be zero (0 KN).
        b. Speed should be Zero (0 Kmph)
        c. Brake should be applied (BC-1/2 is high).
        d. All BUR should be active.
        e. Reverser in neutral position (Node at 570)
         f. Shift MRB & scavnage to BUR-2
 
Software patch should be tried with R0202 & R0203 available in CLW website.

Letter with logic

Letter with schmetic for shifting of MRB and its scavange to BUR-2

Draft MS for energy saving

Regular SOFTWARE for addressing issue of VCB stuck On/Off in 3- Phase Locmotives (21.01.2022) 

Download S/W version R0203

Download S/W version R0202

Letter for regular approval



Trial Test SOFTWARE for DPWCS integeration with CCB Brake system in Three Phase Freigh Loco R0203(13.02.2021)

Download S/W version R0203

Download software in FLG processor for integration of DPWCS with CCB Brake system of M/s KBIL make

This software has to be overwritten on the exisiting trial software R0202  in FLG processor card of VCU only and rest of the processor card software will be same as defined in R0202.

***Remember FLG Processor S/w Version will chnage to WAG9--> 3203 and WAG9H-->4203

Letter with reference for integration of DPWCS with CCB Brake system of M/s KBIL make

 

 

Trial Test SOFTWARE for DPWCS integeration in Three Phase Freigh Loco R0202(18.08.2020)

Download S/W version R0202

Download the software (including .hex, .chk file) in all the processor card of VCU, SR & BUR if the locmotive is of GTO.

Download the software (including .hex, .chk file) in all the processor of MICAS based VCU and please tell IGBT Converter manufcaturers to update the firmware to TCN in place of existing MICAS protocol.

The software has the logics for DPWCS , Consist and other reliabilty meassures like Lifesign, OHE volatge, Vigilance, Speed/Emergency Alarm, VCB/FIlter stuck ON/OFF & Water Closet integration   

Letter for regular approval

Related letter for DPWCS operation

Ref. (i) dated 28.05.20

Ref. (i) dated 17.07.20

Ref. (ii)

Ref. (iii) & Ref. (iv)

 

NEW SOFTWARE for Push Pull Operation in WAP7 LOCOMOTIVE R_2148 (30.07.2019)

Download

Download the software in FLG-1/2, STB-1/2(with New/Old HLC Scheme) and DIA processor card of MICAS based VCU for Push Pull operation.

The Software Version will be 2148 for FLG1 Push Pull scheme, 0147 for STB1/2 with NEW HLC Scheme and 0146 for STB1 with OLD HLC Scheme

Wiring Mdoification

 

NEW SOFTWARE for UPGRADATION OF WAP5 LOCOMOTIVE TO 6000HP R_1146(25.09.2018)

Download
Download the software in FLG-1/2 and SLG-1/2 processor card of MICAS based VCU with GTO SR

 

NEW PARTIAL CAB REDUNANCY SOFTWARE R_0143(14.12.2017)









MS SHEET


 

 

Latest Software for Download (08.09.2015)

Downloadable file


 

Software for WAG-9H

version R_4140

Software for WAG-9

version R_3140

Software for WAP-7

version R_2140

Software for WAP-5

version R_1130

Software for WAP-5
 version R_2130

1.

!DL.zip

!DL.zip

!DL.zip

!DL.zip

2.

!MV.zip

!MV.zip

!MV.zip

!MV.zip

3.

!MWD.zip

!MWD.zip

!MWD.zip

!MWD.zip

4.

SLG_Modified.ZIP

 SLG_Modified.ZIP

SLG_Modified.ZIP 

SLG_Modified.ZIP

SLG_Modified.ZIP 

 

15.03.2017

Note

  1. Please download SLG_modified.ZIP for downloading software in those 3-Phase Locomotives equipped with GTO Traction and Auxiliary Converter.
  2. Modifications carried out for:
  • Increase in temperature settings of SR oil from 64/66 0C to 65/67 0C  
  • Increase in trigger range of temperature disturbance from 10 0C to 25 0C
 17.03.2017

DESCRIPTION         

DOWNLOAD
REMARKS
Common Software for Complete VCU Redundancy for WAG9H
Software
Schematics

  
 
 
20.04.2017
DESCRIPTION
DOWNLOAD
REMARKS
Common Software for Partial VCU Redundancy for WAG9H and WAP7
WAP-7
WAG-9H


  

 



Source : Welcome to CLW Official Website ! CMS Team Last Reviewed on: 19-10-2022  

  Admin Login | Site Map | Contact Us | RTI | Disclaimer | Terms & Conditions | Privacy Policy Valid CSS! Valid XHTML 1.0 Strict

© 2016  All Rights Reserved.

This is the Portal of Indian Railways, developed with an objective to enable a single window access to information and services being provided by the various Indian Railways entities. The content in this Portal is the result of a collaborative effort of various Indian Railways Entities and Departments Maintained by CRIS, Ministry of Railways, Government of India.